BSA

DATASHEET

 

Type: Single Ended Beam
Material: Stainless Steel
Protection: IP 68
Features: Low Profile
Anti-Explosion
Application: Pallet Scales
Hopper Scales
Process Weighing
Food Industries
Overhead Track
In stock N/A .

Description

Celltec load cell BSA is a shear beam load cell and has application in high sensibility weight measurements.

The producer adjusts full scale output of BSA. It makes the load cells to in a way which they are not  much different to each other. In multi load cell weighing systems, calibration of BSA is easily don through the junction box.

The material of this load cell is stainless steel. Also Celltec BSA has IP67 which makes it washable.

 

Applications:

Different classes of  scales for example fixed or mobile scales. Also industrial scales, airport scaled and medical scales for animals.

Variety of ceiling weighing for example elevators and lifters weighing.

It also has application in weighting silos and trunk.

Different types of batching and mixers for asphalt factories, concrete factories, food industry.

Variety of forklift and pallet weighing.

Also it has application in mobile weighing for example mixer feeder and cargo truck.

Additional information

Capacity

250kg, 500kg, 1.0t, 1.5t, 2.0t, 5.0t

Accuracy Class

C3

Max. Number of Verification Intervals (N max)

3000

Minimum Load cell Verification Interval (V min)

Emax/10000

Temperature Effect on Zero (%FS/10°C)

≤ ± 0.0165

Temperature Effect on Sensitivity (%FS/10°C)

≤ ± 0.0137

Combined Error (%FS)

≤ ± 0.0230

Creep (%FS)

≤ ± 0.0165

Output Sensitivity (mV/V)

2.0 ± 0.02

Input Resistance (Ω)

1000 ± 10

Output Resistance (Ω)

1005 ± 5

Insulation Resistance (MΩ)

≥ 5000

Zero Balance (%FS)

1.0

Temperature, Compensated (°C)

-10 ~ +40

Temperature, Operating (°C)

-30 ~ +70

Safe Overload (%FS)

150

Ultimate Overload (%FS)

300

Standard Cable Length (m)

6